1.
Sustain Cities Soc ; 87: 104232, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2183253

ABSTRACT

Under the global landscape of the prolonged COVID-19 pandemic, the number of individuals who need to be tested for COVID-19 through screening centers is increasing. However, the risk of viral infection during the screening process remains significant. To limit cross-infection in screening centers, a non-contact mobile screening center (NCMSC) that uses negative pressure booths to improve ventilation and enable safe, fast, and convenient COVID-19 testing is developed. This study investigates aerosol transmission and ventilation control for eliminating cross-infection and for rapid virus removal from the indoor space using numerical analysis and experimental measurements. Computational fluid dynamics (CFD) simulations were used to evaluate the ventilation rate, pressure differential between spaces, and virus particle removal efficiency in NCMSC. We also characterized the airflow dynamics of NCMSC that is currently being piloted using particle image velocimetry (PIV). Moreover, design optimization was performed based on the air change rates and the ratio of supply air (SA) to exhaust air (EA). Three ventilation strategies for preventing viral transmission were tested. Based on the results of this study, standards for the installation and operation of a screening center for infectious diseases are proposed.

2.
Build Environ ; 227: 109800, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2104465

ABSTRACT

We developed a high-speed filterless airflow multistage photocatalytic elbow aerosol removal system for the treatment of bioaerosols such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Human-generated bioaerosols that diffuse into indoor spaces are 1-10 µm in size, and their selective and rapid treatment can reduce the risk of SARS-CoV-2 infection. A high-speed airflow is necessary to treat large volumes of indoor air over a short period. The proposed system can be used to eliminate viruses in aerosols by forcibly depositing aerosols in a high-speed airflow onto a photocatalyst placed inside the system through inertial force and turbulent diffusion. Because the main component of the deposited bioaerosol is water, it evaporates after colliding with the photocatalyst, and the nonvolatile virus remains on the photocatalytic channel wall. The residual virus on the photocatalytic channel wall is mineralized via photocatalytic oxidation with UVA-LED irradiation in the channel. When this system was operated in a 4.5 m3 aerosol chamber, over 99.8% aerosols in the size range of 1-10 µm were removed within 15 min. The system continued delivering such performance with the continuous introduction of aerosols. Because this system exhibits excellent aerosol removal ability at a flow velocity of 5 m/s or higher, it is more suitable than other reactive air purification systems for treating large-volume spaces.

3.
Comput Electron Agric ; 196: 106907, 2022 May.
Article in English | MEDLINE | ID: covidwho-1763666

ABSTRACT

The distribution of agricultural and livestock products has been limited owing to the recent rapid population growth and the COVID-19 pandemic; this has led to an increase in the demand for food security. The livestock industry is interested in increasing the growth performance of livestock that has resulted in the need for a mechanical ventilation system that can create a comfortable indoor environment. In this study, the applicability of demand-controlled ventilation (DCV) to energy-efficient mechanical ventilation control in a pigsty was analyzed. To this end, an indoor temperature and CO2 concentration prediction model was developed, and the indoor environment and energy consumption behavior based on the application of DCV control were analyzed. As a result, when DCV control was applied, the energy consumption was smaller than that of the existing control method; however, when it was controlled in an hourly time step, the increase in indoor temperature was large, and several sections exceeded the maximum temperature. In addition, when it was controlled in 15-min time steps, the increase in indoor temperature and energy consumption decreased; however, it was not energy efficient on days with high-outdoor temperature and pig heat.

4.
Energy Build ; 230: 110533, 2021 Jan 01.
Article in English | MEDLINE | ID: covidwho-837448

ABSTRACT

The proposed investigation is aimed at providing useful suggestions and guidelines for the renovation of educational buildings, in order to do University classrooms safe and sustainable indoor places, with respect to the 2020 SARS-CoV-2 global pandemic. Classrooms and common spaces have to be thought again, for a new "in-presence" life, after the recent worldwide emergency following the spring 2020 pandemic diffusion of COVID-19. In this paper, starting from a real case study, and thus the architectural and technological refurbishment of an Italian University building (Campobasso, South Italy, cold climate), with the aims of improving the classrooms' quality and safety, a comprehensive approach for the retrofit design is proposed. By taking into account the necessary come back to classrooms starting, hopefully, from the next months (Autumn 2020), experimental studies (monitoring and investigations of the current energy performances) are followed by the coupling of different numerical methods of investigations, and thus building performance simulations, under transient conditions of heat transfer, and computational fluid dynamics studies, to evidence criticalities and potentialities to designers involved in the re-thinking of indoor spaces hosting multiple persons, with quite high occupancy patterns. Both energy impacts, in terms of monthly and annual increase of energy demands due to higher mechanical ventilation, and indoor distribution of microclimatic parameters (i.e., temperature, airspeed, age of air) are here investigated, by proposing new scenarios and evidencing the usefulness of HVAC systems, equipment (e.g., sensible heat recovery, without flows' contamination) and suitability of some strategies for the air distribution systems (ceiling squared and linear slot diffusers) compared to traditional ones.